DW-R1X16
Availability: | |
---|---|
1×N (N≥2) PLC Splitter (with Connectors)
Parameter | 1X2 | 1x4 | 1x8 | 1x16 | 1x32 | 1x64 | |
Wavelength (nm) | 1260 ~ 1650 | ||||||
IL (dB) | ≤4.1 | ≤7.4 | ≤10.5 | ≤13.8 | ≤17.1 | ≤20.4 | |
Uniformity (dB) | ≤0.6 | ≤0.7 | ≤0.8 | ≤1.0 | ≤1.5 | ≤2.0 | |
RL (dB) | ≥50 (PC), ≥55 (APC) | ||||||
PDL (dB) | ≤0.15 | ≤0.2 | ≤0.2 | ≤0.3 | ≤0.3 | ≤0.3 | |
Directivity (dB) | ≥55 | ≥55 | ≥55 | ≥55 | ≥55 | ≥55 | |
Environment | Operating temp (℃) | -40~85℃ | |||||
Storage temp (℃) | -40~85℃ | ||||||
Humidity | ≤95% (+40℃) | ||||||
Atmospheric pressure | 62~106kPa | ||||||
Fiber | SM, G657A or Customized | ||||||
Connector | SC, FC |
Remark: Above parameter is result of the test in room temperature, which include the RL of connector.
2×N (N≥2) PLC Splitter (with Connectors)
Parameter | 2X2 | 2x4 | 2x8 | 2x16 | 2x32 | 2x64 | |
Wavelength (nm) | 1260 ~ 1650 | ||||||
IL (dB) | ≤4.4 | ≤7.7 | ≤10.8 | ≤14.1 | ≤17.4 | ≤20.7 | |
Uniformity (dB) | ≤0.6 | ≤0.7 | ≤0.8 | ≤1.2 | ≤1.5 | ≤2.0 | |
RL (dB) | ≥50 (PC), ≥55 (APC) | ||||||
PDL (dB) | ≤0.2 | ≤0.2 | ≤0.3 | ≤0.3 | ≤0.3 | ≤0.4 | |
Directivity (dB) | ≥55 | ≥55 | ≥55 | ≥55 | ≥55 | ≥55 | |
Environment | Operating temp (℃) | -40~85℃ | |||||
Storage temp (℃) | -40~85℃ | ||||||
Humidity | ≤95% (+40℃) | ||||||
Atmospheric pressure | 62~106kPa | ||||||
Fiber | SM, G657A or Customized | ||||||
Connector | SC, FC |
Remark: Above parameter is result of the test in room temperature, which include the RL of connector.
Type | Requirement | |
W x H x D (mm) | Remark | |
N: 2~N: 32 | 1U, (482±2) mm x (44±0.5) mm x (200±2) mm | width of rack without bracket is 433mm, tolerances is ±2mm. |
1×N (N≥2) PLC Splitter (with Connectors)
Parameter | 1X2 | 1x4 | 1x8 | 1x16 | 1x32 | 1x64 | |
Wavelength (nm) | 1260 ~ 1650 | ||||||
IL (dB) | ≤4.1 | ≤7.4 | ≤10.5 | ≤13.8 | ≤17.1 | ≤20.4 | |
Uniformity (dB) | ≤0.6 | ≤0.7 | ≤0.8 | ≤1.0 | ≤1.5 | ≤2.0 | |
RL (dB) | ≥50 (PC), ≥55 (APC) | ||||||
PDL (dB) | ≤0.15 | ≤0.2 | ≤0.2 | ≤0.3 | ≤0.3 | ≤0.3 | |
Directivity (dB) | ≥55 | ≥55 | ≥55 | ≥55 | ≥55 | ≥55 | |
Environment | Operating temp (℃) | -40~85℃ | |||||
Storage temp (℃) | -40~85℃ | ||||||
Humidity | ≤95% (+40℃) | ||||||
Atmospheric pressure | 62~106kPa | ||||||
Fiber | SM, G657A or Customized | ||||||
Connector | SC, FC |
Remark: Above parameter is result of the test in room temperature, which include the RL of connector.
2×N (N≥2) PLC Splitter (with Connectors)
Parameter | 2X2 | 2x4 | 2x8 | 2x16 | 2x32 | 2x64 | |
Wavelength (nm) | 1260 ~ 1650 | ||||||
IL (dB) | ≤4.4 | ≤7.7 | ≤10.8 | ≤14.1 | ≤17.4 | ≤20.7 | |
Uniformity (dB) | ≤0.6 | ≤0.7 | ≤0.8 | ≤1.2 | ≤1.5 | ≤2.0 | |
RL (dB) | ≥50 (PC), ≥55 (APC) | ||||||
PDL (dB) | ≤0.2 | ≤0.2 | ≤0.3 | ≤0.3 | ≤0.3 | ≤0.4 | |
Directivity (dB) | ≥55 | ≥55 | ≥55 | ≥55 | ≥55 | ≥55 | |
Environment | Operating temp (℃) | -40~85℃ | |||||
Storage temp (℃) | -40~85℃ | ||||||
Humidity | ≤95% (+40℃) | ||||||
Atmospheric pressure | 62~106kPa | ||||||
Fiber | SM, G657A or Customized | ||||||
Connector | SC, FC |
Remark: Above parameter is result of the test in room temperature, which include the RL of connector.
Type | Requirement | |
W x H x D (mm) | Remark | |
N: 2~N: 32 | 1U, (482±2) mm x (44±0.5) mm x (200±2) mm | width of rack without bracket is 433mm, tolerances is ±2mm. |